dc.description© 2024 Authors. This document is the published version of a published work that appeared in final form in Energies This document is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by/4.0 To access the final edited and published work see: https://doi.org/10.3390/en17225703-
dc.description.abstractSolar electric and solar thermal energies are often considered as part of the solution to the current energy emergency. The pipes of flat plate solar devices are normally heated by their upper surfaces giving rise to an asymmetric temperature field in the bulk of the fluid, which influences the heat transfer process. In the present work, a study of the characteristic length of tubes, or most efficient distance at which heat transfer occurs, in flat photovoltaic-thermal (PVT) hybrid solar devices has been carried out using three heat transfer fluids: water, [Emim]Ac ionic liquid and ionanofluid of graphene nanoparticles suspended in the former ionic liquid. The mean objective of the study was to know whether the heat transfer occurs in optimal conditions. Experimental measurements have been made on a commercial PVT device, and numerical simulations have been performed using the HEATT® platform to determine the characteristic length of the process. The tests conducted showed a clear improvement in the temperature jump of the fluid inside the collector when INF is used compared to water and ionic liquid and even a higher overall energy efficiency. Electricity generation is not greatly affected by the fluid used, although it is slightly higher when water is used. Slower fluid velocities are recommended if high fluid outlet temperatures are the goal of the application, but this penalizes the overall thermal energy production. The characteristic process length is not typically achieved in parallel tube PVT collectors with ordinary flow rates, which would require a speed, and consequently, a flow rate, about 10 times lower, which penalizes the performance (up to four times), although it increases the fluid outlet temperature by 234%, which can be very interesting in certain applications. Ionanofluids may in the medium term become an alternative to water in flat plates or vacuum solar collectors for applications with temperatures close to or above 100 °C, when their costs will hopefully fall. The results and methodology developed in this work are applicable to solar thermal collectors other than PVT collectors.es
dc.formatapplication/pdfes
dc.format.extent17-
dc.languageenges
dc.publisherMDPIes
dc.relationPROYECTO 1 Ámbito del proyecto: nacional Agencia financiadora: Agencia estatal de investigación y Ministerio de Ciencia, Innovación y Universidades Convocatoria: 2020 Nombre del proyecto: BIOMATERIALES EN NANOINGENIERÍA: PRODUCCIÓN Y APLICACIONES EN TERAPIAS ANTICANCERÍGENA, ANTIBACTERIANA Y ANTIVIRAL Código o número del acuerdo de subvención: PID2020-113081RB-I00 PROYECTO 2 Ámbito del proyecto: nacional Agencia financiadora: Agencia estatal de investigación y Ministerio de Ciencia, Innovación y Universidades Convocatoria: 2021 Nombre del proyecto: Aplicaciones de los líquidos iónicos como microcápsulas para la captura selectiva de CO2 y como ionanofluidos para energía solar Código o número del acuerdo de subvención: TED2021-130389B-C21 PROYECTO 3 Ámbito del proyecto: regional Agencia financiadora: Fundación Séneca Convocatoria: 2022 Nombre del proyecto: Nanotecnología verde aplicada a la mitigación del cambio climático Código o número del acuerdo de subvención: Ref. 22129-PI-22es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectSolar energyes
dc.subjectPhotovoltaic-thermal collectors (PVT)es
dc.subjectCharacteristic lengthes
dc.subjectIonanofluidses
dc.subjectHEATT®es
dc.titleStudy of Ionanofluids Behavior in PVT Solar Collectors: Determination of Thermal Fields and Characteristic Length by Means of HEATT® Platformes
dc.typeinfo:eu-repo/semantics/articlees
dc.relation.publisherversionhttps://www.mdpi.com/1996-1073/17/22/5703-
dc.identifier.doihttps://doi.org/10.3390/en17225703-
dc.contributor.departmentDepartamento de Ingeniería Química-
Aparece en las colecciones:Artículos

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
energies-17-05703-v2.pdf10,49 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de Digitum están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.