Por favor, use este identificador para citar o enlazar este ítem: 10.1159/000516465

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorTaboada Martín, Rubén-
dc.contributor.authorArribas Leal, José María-
dc.contributor.authorEsteve Pastor, María Asunción-
dc.contributor.authorAbellán Alemán, José-
dc.contributor.authorMarín, Francisco-
dc.contributor.authorRivera Caravaca, José Miguel-
dc.contributor.authorCánovas López, Sergio-
dc.date.accessioned2024-07-18T11:16:11Z-
dc.date.available2024-07-18T11:16:11Z-
dc.date.issued2021-06-11-
dc.identifier.citationCardiology (2021) 146 (5): 656–666.es
dc.identifier.issn0300-8932-
dc.identifier.issn1579-2242-
dc.identifier.urihttp://hdl.handle.net/10201/143220-
dc.description.abstractBackground: The use of rapid deployment and sutureless aortic prostheses is increasing. Previous reports have shown promising results on haemodynamic performance and mortality rates. However, the impact of these bioprostheses on left ventricular mass (LVM) regression remains unknown. We decided to study the changes in remodelling and LVM regression in isolated severe aortic stenosis treated with conventional or Perceval® or Intuity® valves. Method and Results: From January 2011 to January 2016, 324 bioprostheses were implanted in our centre. The collected characteristics were divided into 3 groups: conventional valves, Perceval®, and Intuity®, and they were analysed after 12 months. There were 183 conventional valves (56%), 72 Perceval® (22%), and 69 Intuity® (21.2%). The statistical analysis showed significant differences in transprosthetic postoperative peak gradient (23 [18–29] mm Hg vs. 21 [16–29] mm Hg and 18 [14–24] mm Hg, p < 0.001), ventricular mass electrical criteria regression (Sokolow and Cornell products), and 1-year survival (90 vs. 93% and 97%, log rank p value = 0.04) in conventional, Perceval®, and Intuity® groups. Conclusions: We observed differences in haemodynamic, electrocardiographic, and echocardiographic parameters related to the different types of prosthesis. Patients with the Intuity® prosthesis had the highest reduction in peak aortic gradient and the higher ventricular mass regression. Besides, patients with the Intuity® prosthesis had less risk of mortality during follow-up than the other two groups. Further studies are needed to confirm these findings.es
dc.formatapplication/pdfes
dc.format.extent11es
dc.languageenges
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAortic stenosises
dc.subjectSutureless aortic prostheseses
dc.subjectAortic valve surgeryes
dc.subjectLeft ventricular mass regressiones
dc.titleComparison of Aortic Gradient and Ventricular Mass after Valve Replacement for Aortic Stenosis with Rapid Deployment, Sutureless, and Conventional Bioprostheseses
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1159/000516465-
Aparece en las colecciones:Artículos: Cirugía, Pediatría y Obstetricia y Ginecología



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons