Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.2319/032711-216.1

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorVicente Hernández, Ascensión-
dc.contributor.authorMolina, Sara-
dc.contributor.authorOrtiz Ruiz, Antonio José-
dc.contributor.authorBravo González, Luis Alberto-
dc.date.accessioned2024-06-25T08:16:18Z-
dc.date.available2024-06-25T08:16:18Z-
dc.date.issued2011-08-10-
dc.identifier.citationThe Angle Orthodontist (2012) 82 (2): 346–350es
dc.identifier.issnPrint: 0003-3219-
dc.identifier.issnElectronic: 1945-7103-
dc.identifier.urihttp://hdl.handle.net/10201/142631-
dc.description© 2012 by The EH Angle Education and Research Foundation, Inc. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/. This document is the Published version of a Published Work that appeared in final form in Angle Orthodontist. To access the final edited and published work see https://doi.org/10.2319/032711-216.1-
dc.description.abstractObjective: To evaluate the effect of food-simulating liquids on bond strengths of brackets bonded with a HEMA-free and a HEMA-containing self-etching primer. Materials and Methods: Brackets were bonded to 280 bovine incisors that were divided into two groups: (1) Adper Prompt-L-Pop (Adper PLP)/Transbond-XT and (2) Transbond Plus self-etching primer (TSEP, HEMA-free)/Transbond-XT. Each group was evaluated under different storage conditions: 24 hours in water, thermocycling (T), T/12 weeks in water, T/12 weeks in 10% ethanol, T/12 weeks in 50% ethanol, T/12 weeks in 3% acetic acid, and T/12 weeks in olive oil. Shear bond strength was measured with a universal test machine. Results: TSEP and Adper PLP showed a significantly higher bond strength at 24 hours than at T/12 weeks in 50% ethanol (P  =  .000). For Adper PLP, the bond strength at 24 hours was significantly higher than T/12 weeks in water (P  =  .000). Significant differences were not detected between the two bonding procedures for the different storage conditions (P > .05). Conclusion: Owing to its hydrophilic nature, the bond strength produced by Adper PLP (a HEMA-containing self-etching primer) decreased significantly after T/12 weeks in water. Brackets bonded with both TSEP and Adper PLP showed significantly higher bond strengths at 24 hours than at T/12 weeks in 50% ethanol, probably due to the effect of ethanol at 50% on Transbond-XT.es
dc.formatapplication/pdfes
dc.format.extent5es
dc.languageenges
dc.publisherEH Angle Education Research Foundation, Inc.es
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFood-simulating liquidses
dc.subjectHEMA-free self-etching primeres
dc.subjectHEMA-containing self etching primeres
dc.subjectShear bondes
dc.titleInfluence of food-simulating liquids on bond strength of brackets bonded with a HEMA-free and HEMA-containing self-etching primeres
dc.typeinfo:eu-repo/semantics/articlees
dc.relation.publisherversionhttps://meridian.allenpress.com/angle-orthodontist/article/82/2/346/57450/Influence-of-food-simulating-liquids-on-bond-
dc.identifier.doihttps://doi.org/10.2319/032711-216.1-
dc.contributor.departmentDermatología, Estomatología, Radiología y Medicina Física-
Aparece en las colecciones:Artículos

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
032711-216_1.pdf98,28 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons