Por favor, use este identificador para citar o enlazar este ítem:
https://doi.org/10.2319/032711-216.1


Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Vicente Hernández, Ascensión | - |
dc.contributor.author | Molina, Sara | - |
dc.contributor.author | Ortiz Ruiz, Antonio José | - |
dc.contributor.author | Bravo González, Luis Alberto | - |
dc.date.accessioned | 2024-06-25T08:16:18Z | - |
dc.date.available | 2024-06-25T08:16:18Z | - |
dc.date.issued | 2011-08-10 | - |
dc.identifier.citation | The Angle Orthodontist (2012) 82 (2): 346–350 | es |
dc.identifier.issn | Print: 0003-3219 | - |
dc.identifier.issn | Electronic: 1945-7103 | - |
dc.identifier.uri | http://hdl.handle.net/10201/142631 | - |
dc.description | © 2012 by The EH Angle Education and Research Foundation, Inc. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/. This document is the Published version of a Published Work that appeared in final form in Angle Orthodontist. To access the final edited and published work see https://doi.org/10.2319/032711-216.1 | - |
dc.description.abstract | Objective: To evaluate the effect of food-simulating liquids on bond strengths of brackets bonded with a HEMA-free and a HEMA-containing self-etching primer. Materials and Methods: Brackets were bonded to 280 bovine incisors that were divided into two groups: (1) Adper Prompt-L-Pop (Adper PLP)/Transbond-XT and (2) Transbond Plus self-etching primer (TSEP, HEMA-free)/Transbond-XT. Each group was evaluated under different storage conditions: 24 hours in water, thermocycling (T), T/12 weeks in water, T/12 weeks in 10% ethanol, T/12 weeks in 50% ethanol, T/12 weeks in 3% acetic acid, and T/12 weeks in olive oil. Shear bond strength was measured with a universal test machine. Results: TSEP and Adper PLP showed a significantly higher bond strength at 24 hours than at T/12 weeks in 50% ethanol (P = .000). For Adper PLP, the bond strength at 24 hours was significantly higher than T/12 weeks in water (P = .000). Significant differences were not detected between the two bonding procedures for the different storage conditions (P > .05). Conclusion: Owing to its hydrophilic nature, the bond strength produced by Adper PLP (a HEMA-containing self-etching primer) decreased significantly after T/12 weeks in water. Brackets bonded with both TSEP and Adper PLP showed significantly higher bond strengths at 24 hours than at T/12 weeks in 50% ethanol, probably due to the effect of ethanol at 50% on Transbond-XT. | es |
dc.format | application/pdf | es |
dc.format.extent | 5 | es |
dc.language | eng | es |
dc.publisher | EH Angle Education Research Foundation, Inc. | es |
dc.relation | Sin financiación externa a la Universidad | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Food-simulating liquids | es |
dc.subject | HEMA-free self-etching primer | es |
dc.subject | HEMA-containing self etching primer | es |
dc.subject | Shear bond | es |
dc.title | Influence of food-simulating liquids on bond strength of brackets bonded with a HEMA-free and HEMA-containing self-etching primer | es |
dc.type | info:eu-repo/semantics/article | es |
dc.relation.publisherversion | https://meridian.allenpress.com/angle-orthodontist/article/82/2/346/57450/Influence-of-food-simulating-liquids-on-bond | - |
dc.identifier.doi | https://doi.org/10.2319/032711-216.1 | - |
dc.contributor.department | Dermatología, Estomatología, Radiología y Medicina Física | - |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
032711-216_1.pdf | 98,28 kB | Adobe PDF | ![]() Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons