Título: Estudio de los efectos ópticos de las cataratas y su corrección mediante manipulado del frente de onda
Otros títulos: Study of the optical effect of cataracts and its correction using wavefront shaping
Fecha de publicación: 29-mar-2019
Fecha de defensa / creación: 22-mar-2019
Editorial: Universidad de Murcia
Materias relacionadas: CDU::6 - Ciencias aplicadas::61 - Medicina::617 - Cirugía. Ortopedia. Oftalmología
Palabras clave: Oftalmología
Óptica Fisiológica
Física de la visión
Instrumentos ópticos
Resumen: Las cataratas son una patología caracterizada por la opacificación del cristalino, la cual incrementa la cantidad de aberraciones oculares y dispersión (o scattering) intraocular. En consecuencia, las cataratas vuelven borrosas y reducen el contraste de las imágenes en la retina. La solución actual a esta patología es la cirugía, donde el cristalino afectado es extraído y reemplazado por una lente intraocular. Sin embargo, los requerimientos para practicar de forma segura este procedimiento no permiten cubrir su demanda, ubicando las cataratas como la primera causa de ceguera reversible en el mundo. Por lo tanto, resulta necesaria una alternativa no invasiva (basada únicamente en métodos ópticos). La búsqueda de tal alternativa es un reto abierto pues, aunque la óptica adaptativa ha demostrado ser una herramienta efectiva para la medición y manipulación de las aberraciones presentes en el ojo, la alta cantidad de aberraciones y scattering en los ojos cataratosos limita el desempeño de estos sistemas. En la última década, la técnica de manipulación del frente de onda (WS, del inglés Wavefront Shaping) ha sido aplicada para la formación de imágenes a través de medios turbios. En esta tesis, la técnica WS es propuesta para corregir los efectos de las cataratas de forma no invasiva. Así, el objetivo general es evaluar el desempeño de la técnica para esta aplicación particular en un banco óptico, evitando la influencia de los fenómenos oculares dinámicos que son inherentes a una implementación in-vivo. Inicialmente, se desarrolló un modelo de frentes de onda oculares para reproducir la función de punto esparcido (PSF, del inglés Point Spread Function) para un observador estándar con diferentes cantidades de scattering intraocular, mediante la suma ponderada de perturbaciones de fase con bajas y altas frecuencias espaciales. El modelo permitió reproducir los siguientes fenómenos ópticos oculares y compararlos con mediciones experimentales y clínicas previamente publicadas: la dependencia del scattering intraocular con la longitud de onda, el efecto del envejecimiento sobre las aberraciones de alto orden y la razón de Strehl, y la apariencia de la corona ciliar. Los frentes de onda oculares fueron reproducidos en una pantalla de cristal líquido sobre silicio (LCoS, del inglés Liquid Crystal on Silicon) como modulador espacial de luz para generar experimentalmente las cantidades de scattering intraocular. El LCoS fue incorporado a un simulador visual para evaluar los efectos del scattering intraocular en la agudeza visual y la sensibilidad al contraste, tanto en fóvea como dos excentricidades del campo visual nasal. Las relaciones entre cantidades inducidas de scattering y tales cantidades psicofísicas fueron establecidas. Además, a partir de esos resultados, se explicaron los modestos beneficios de las cirugías de cataratas en pacientes con degeneración macular. Un instrumento fue desarrollado para evaluar el desempeño de la técnica WS en la corrección de las cataratas simuladas. Los efectos de tres niveles de catarata fueron generados y corregidos simultáneamente usando un dispositivo LCoS, simulando un paso simple por el medio ocular. La calidad de la corrección fue valorada objetiva y subjetivamente a través de las siguientes métricas: el parámetro de mejoramiento de la PSF, la razón visual de Strehl, los coeficientes de correlación entre imágenes extendidas con iluminación espacialmente incoherente y la agudeza visual. Según los resultados, el principal efecto de la técnica WS es el desemborronamiento de las imágenes. Sin embargo, cálculos numéricos adicionales revelaron que el scattering no fue reducido, lo que disminuiría el contraste de las imágenes vistas a través del corrector. Se propuso una estrategia para superar esta limitación de la técnica. El instrumento desarrollado fue ligeramente modificado para evaluar el desempeño de la técnica WS simulando un doble paso a través del medio ocular cataratoso. Los resultados muestran que, si bien la PSF coherente fue optimizada luego del doble paso, esta corrección no beneficiaría de manera suficiente la calidad visual. Finalmente, algunas recomendaciones son dadas con el fin de aumentar el beneficio de la técnica WS en una futura implementación in-vivo.
Cataract is one of the main causes of visual impairment in the world. It increases both intraocular scattering and aberrations because microscopic and macroscopic changes of the refractive index in the lens. Consequently, the effect of cataracts is the simultaneous blurring and reduction of the contrast in the retinal images. The intensity of the effect is associated to the amount of straylight, which is a quantification of the impinging light into the eye deviated to large retinal angles (i.e., larger than one degree). The current treatment of cataract is surgery, where the lens is extracted and replaced with an intraocular lens. However, the requirements for its safe practice have not allowed to cover its global demand, especially in developing countries. Therefore, a non-invasive optical technique is appealing, and its development is an open challenge. There is a unique precedent reported in 1973, where the phase of an extracted lens was retrieved using holography for its posterior phase conjugation. Moreover, the performance of current adaptive optics systems is limited by the large amount of scattering that is present in the cataractous eyes. On the other hand, wavefront-shaping (WS) technique was developed for imaging through opaque samples. In this work, the WS technique is proposed to partially correct the effects of cataracts non-invasively in-vivo, being the objective to evaluate its performance for this application. The technique was tested in an optical bench to avoid the influence of the dynamics of ocular phenomena which is inherent in an in-vivo implementation. As first step, a model was developed to reproduce the ocular point spread function (PSF) with different amounts of straylight through the weighted summation of both low and high spatial frequency phase perturbations at the entrance pupil of the eye. The model was initially tested by numerically calculating the following ocular phenomena and their comparison with previously reported experimental and clinical studies: aging effects on high order aberrations and Strehl ratio, the wavelength dependence of straylight and the ciliary corona. The calculated phase maps by the model were displayed on a liquid crystal on silicon (LCoS) device as spatial light modulator to experimentally generate the amounts of straylight, measured by the optical integration method. Moreover, the model was incorporated in a visual simulator to evaluate the effects of straylight on the visual acuity, the contrast sensitivity and the glare sensitivity, in fovea and two eccentricities of the visual nasal field. In this way, the relationships between the amount of straylight and these measurements of the visual function were established. Furthermore, the modest benefits of the cataract surgery with preexisting retinal diseases can be explained from these measurements. An instrument was developed for the experimental evaluation of the WS technique’s performance in the correction of simulated cataracts. It simultaneously generates and corrects the effects of cataracts using a double-pass through a single LCoS device. The following process were done for the incorporation of the LCoS device: phase calibration, optimization of the phase modulation, suppression of the unmodulated light, and compensation of its inherent aberrations. Thus, the effects of three levels of cataract, with associated logarithmic amounts of straylight ranged from 1.75 to 2.25, were corrected using seven different spatial resolutions of the correcting phase maps. The quality of the correction was initially evaluated, considering one pass through the affected ocular media, by means of the following objective and subjective metrics: the enhancement of the PSF, the visual Strehl ratio, the correlation coefficients and the visual acuity. According to these measurements, the main effect of the WS technique is deblurring. Finally, the developed instrument was slightly modified to evaluate the performance of the WS technique considering symmetrical and asymmetrical double-passes through the cataractous ocular media. Although the WS technique optimized the double-pass PSFs, it did not mean a benefit in the quality of vision. Therefore, some suggestions are given to obtain a visual benefit from the implementation of WS in double-pass.
Autor/es principal/es: Arias Gallego, Augusto
Director/es: Artal Soriano, Pablo
Fernández Martínez, Enrique Josua
Facultad/Departamentos/Servicios: Escuela Internacional de Doctorado
Forma parte de: Proyecto de investigación:
URI: http://hdl.handle.net/10201/68710
Tipo de documento: info:eu-repo/semantics/doctoralThesis
Número páginas / Extensión: 105
Derechos: info:eu-repo/semantics/openAccess
Aparece en las colecciones:Ciencias de la Salud

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
THESIS_AUGUSTO.pdf6,15 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons