Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10201/35246

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.advisorBaró Vidal, Arturo M.-
dc.contributor.advisorColchero Paetz, Jaime Virgilio-
dc.contributor.authorLópez Elvira, Elena-
dc.contributor.otherFacultad de Químicaes
dc.date.accessioned2013-06-11T06:51:17Z-
dc.date.available2013-06-11T06:51:17Z-
dc.date.created2013-06-05-
dc.date.issued2013-06-11-
dc.identifier.urihttp://hdl.handle.net/10201/35246-
dc.description.abstractEn este trabajo se ha desarrollado un microscopio de fuerzas (SFM) provisto de microscopía electrostática (ESFM) y microscopía Kelvin (KPM) especialmente diseñado para integrarse en un microscopio óptico invertido de forma que combine simultáneamente las técnicas de campo cercano con las técnicas ópticas. Tras una introducción (capítulo 1) y la descripción de las técnicas experimentales (capítulo 2), se detallan las características del diseño de un primer prototipo, así como las medidas realizadas con él con el fin de comprobar su correcto funcionamiento (capítulo 3). El capítulo 4 muestra el diseño de un segundo prototipo con las mejoras que incorpora respecto al primero, que lo convierten en un sistema más completo, versátil y fácil de manejar. También figuran las medidas realizadas con él. El capítulo 5 muestra un estudio de fotodegradación en polímeros conductores en función de la radiación incidente, combinando microscopía electrostática y Kelvin con técnicas ópticas. Palabras clave Microscopía de Fuerzas (SFM) Microscopía óptica Microscopía Electrostática (ESFM) Microscopía Kelvin (KPM) Polímeros conductores Abstract In this work we have developed an Scanning Force Microscope (SFM) equipped with Electrostatic and Kelvin Probe Microscopy (ESFM, KPM), specially designed for integration into an inverted optical microscope in order to combine near-field techniques with optical techniques. After an introduction (Chapter 1) and the description of the experimental techniques (Chapter 2), are described the features of the design of a first prototype, as well as the measurements made with it in order to verify proper operation (Chapter 3). The Chapter 4 shows the design of a second prototype that incorporates the improvements over the first, making it more comprehensive, versatile and easy to handle. Also are shown the measurements performed with it. The Chapter 5 shows a photodegradation study of conductive polymers as a function of incident radiation combining KPM with optical techniques. Keywords Scanning Force Microcopy (SFM) Optical Microscopy Electrostatic Scanning Force Microcopy (ESFM) Kelvin Probe Microscopy (KPM) Conducting polymerses
dc.formatapplication/pdfes
dc.format.extent156-
dc.languagespaes
dc.relation.ispartofProyecto de investigación:es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectMicroscopía ópticaes
dc.subject.other68 - Industrias, oficios y comercio de artículos acabados. Tecnología cibernética y automáticaes
dc.titleDesarrollo de un sistema combinado de microscopía óptica y microscopía de fuerzas.es
dc.typeinfo:eu-repo/semantics/doctoralThesises
Aparece en las colecciones:Ciencias

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
TesisDoctoral_ElenaLopezElvira.pdf27,4 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons