Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10201/28507

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.advisorCalvo Guirado, José Luis-
dc.contributor.advisorMaté Sánchez, José Eduardo-
dc.contributor.advisorDelgado Ruiz, Rafael Arcesio-
dc.contributor.authorPérez-Albacete Martínez, Carlos-
dc.contributor.otherFacultad de Medicinaes
dc.date.accessioned2012-09-18T11:46:33Z-
dc.date.available2012-09-18T11:46:33Z-
dc.date.issued2012-09-18-
dc.identifier.urihttp://hdl.handle.net/10201/28507-
dc.description.abstractINTRODUCCIÓN A pesar del extendido uso de los implantes de Titanio, existen algunas desventajas con respecto a estos. Por ello, se ha sugerido el uso de implantes de Zirconia como alternativa. OBJETIVOS Cuantificar la fuerza de integración y la composición elemental de los implantes. Cuantificar y comparar BIC y reabsorción crestal. MATERIAL Y MÉTODOS 48 implantes (Titanio y Zirconia) fueron introducido en 6 American Fox Hound. RESULTADOS No diferencias significativas en la estabilidad primaria y secundaria. Calcio, Oxígeno y Fósforo fuero significativamente mayores en los implantes de titanio a 3 meses. No diferencias significativas en BIC. A tres meses, la pérdida de hueso crestal fue significativamente mayor en Titanio. CONCLUSIONES No diferencias significativas en la estabilidad primaria y secundaria. No diferencias significativas en el porcentaje de Calcio. Tratamiento de superficie usando laser de femtosegundo aumenta la oseointegración del grupo Zirconia. A tres meses, reabsoción crestal fue mayor en Zirconia. BACKGROUND Despite of extended use of Titanium implants, there are some disadvantages respects to them. It is been suggested the use of Zirconia implants as an alternative. OBJETIVES Quantifying mechanical strength and elemental composition of implants. Measure and compare BIC and crestal bone loss. MATHERIAL AND METHODS 48 implants (Titanium and Zirconia) were introduced at Six American Fox Hound. RESULTS No significant differences at initial primary and secondary stability. Carbon, Oxygen and Phosphorum were significantly higher at Titanium implants at three months. BIC between groups didn´t show significant differences. At three months, crestal bone loss was significantly lower at Titanium implants. CONCLUSIONS No differences at initial primary and secondary implant stability between groups. No differences at Calcium percentage at groups at three months of study. Surface treatment by using femtosecond laser increase osseointegration at Zirconia implants. At three months of study, crestal bone loss was higher at Zirconia implants.es
dc.formatapplication/pdfes
dc.format.medium137-
dc.languagespaes
dc.relation.ispartofProyecto de investigación:es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectImplantes dentarioses
dc.subject.other616.3 - Patología del aparato digestivo. Odontologíaes
dc.titleValoración mecánica, histológica e histomorfométrica de implantes dentales de zirconia modificados por láser de femtosegundo vs implantes de titanio en hueso cicatrizado : estudio experimental en perros american fox hound a tres meseses
dc.typeinfo:eu-repo/semantics/doctoralThesises
Aparece en las colecciones:Ciencias de la Salud

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
TESIS R3.pdf5,83 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons