Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10201/25560

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorSimarro Blasco, J.A.es
dc.contributor.authorNoheda Blasco, M.C.es
dc.contributor.authorBascuñana Blasco, M.-
dc.contributor.authorNoheda Recuenco, M.-
dc.contributor.authorTolmo Aranda, I.-
dc.contributor.authorRomero Carralero, M.I.-
dc.date.accessioned2011-12-12T08:42:22Z-
dc.date.available2011-12-12T08:42:22Z-
dc.date.issued2011-
dc.identifier.issn1695-6141es
dc.identifier.urihttp://hdl.handle.net/10201/25560-
dc.description.abstractEn la práctica clínica, la tensión arterial es un parámetro importante en la valoración hemodinámica del paciente crítico. Existen dos formas de medición: Presión Invasiva (PI) y Presión No Invasiva (PNI). Como objetivos nos planteamos comparar la diferencia entre ambas formas de medición, valorar las posibles diferencias por la localización arterial, edad y sexo, valorar la influencia de la ventilación mecánica, drogas inotrópicas y antecedentes personales en la diferencia de Presión arterial Invasiva (PI) respecto a la Presión arterial No Invasiva (PNI). Identificar su significación clínica y estimar la fiabilidad de la PNI. Hicimos un estudio descriptivo, longitudinal y comparativo de marzo a diciembre 2008. Se analizó sexo, edad y localización arterial (hemicuerpo y arteria). Incluimos pacientes con arteria con curva óptima y calibración en el momento de medición en decúbito supino. Se tomó la PNI en ambos brazos con 5 minutos de diferencia, registrando la PI al mismo tiempo. Análisis con el Spss 15.0. Se analizó la diferencia en 109 pacientes con diferencias estadísticamente significativas en algún parámetro analizado. Como conclusiones y discusión planteamos que las diferencias encontradas no son clínicamente significativas y por tanto la PI y la PNI son fiables en estado óptimo de calibración.es
dc.description.abstractABSTRACT In clinical practice, blood pressure is an important parameter in patient critic hemodynamic valuation. There are two ways of measuring: Invasive Pressure (IP) and Non Invasive Pressure (NIP). As objectives, we set ourselves the task of comparing the difference between both forms of measurement, assessing the possible differences by arterial location, age and sex, assessing the influence of mechanical ventilation, inotropic drugs and casework in invasive blood pressure difference (IP) and non invasive arterial pressure (NIP). We sought to identify its clinical significance and estimate the reliability of the NIP. We conducted a descriptive, longitudinal and comparative study between March and December 2008. Sex, age and arterial location (hemi-body and artery) were analyzed. We have included patients with artery with optimal curve and calibration at the time of measurement in decubitus. NIP was taken in both arms at an interval of five minutes, and IP was recorded at the same time. Analysis was with SPSS 15.0. The difference was analyzed in 109 patients with statistically significant differences in any scanned parameters. Under discussion and conclusions we propose that the differences found are not clinically significant and therefore the IP and the NIP are reliable in optimal calibration state.-
dc.formatapplication/pdfes
dc.format.extent9es
dc.languagespaes
dc.publisherMurcia : Servicio de Publicaciones de la Universidad de Murciaes
dc.relation.ispartofEnfermería globales
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectPresión arteriales
dc.subjectCuidados intensivoses
dc.subjectBlood pressure-
dc.subjectIntensive care-
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicina::614 - Higiene y salud pública. Contaminación. Prevención de accidentes. Enfermeríaes
dc.titleEstudio comparativo de la presión arterial invasiva frente a la presión arterial no invasiva. Valoración de la diferenciaes
dc.title.alternativeComparative study of invasive blood pressure versus non-invasive blood pressure-
dc.typeinfo:eu-repo/semantics/articlees
Aparece en las colecciones:Vol.10 , Nº 24 (2011)



Los ítems de Digitum están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.