Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10201/20784

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorvon Bartheld, C.S.es
dc.date.accessioned2011-05-11T10:58:07Z-
dc.date.available2011-05-11T10:58:07Z-
dc.date.issued2002-
dc.identifier.issn0213-3911es
dc.identifier.urihttp://hdl.handle.net/10201/20784-
dc.description.abstractInvestigators must choose between counting methods to quantify microscopic particles in tissues. The c o nventional profile-based ("model-based" or "2D-") counting methods have been criticized for their potential biases due to assumptions about shapes, sizes, and orientation of particles when converting profile counts into cell numbers. New stereological methods ("designbased" or "3D-") methods such as the optical disector or p hysical disector were initially introduced as being inherently unbiased. Recent calibration analyses and comparisons of results from different investigators have r evealed the potential for significant biases in the most efficient and most frequently used design-based method, the optical disector. This rev i ew aims to objective l y assess the strengths and limitations of current profi l e - and disector-based cell counting methods by examination of studies in which these methods have been calibrated against the "gold-standard", counts obtained by 3-dimensional reconstruction of serial sections. Advantages and disadvantages of each counting method and the associated embedding and sectioning techniques are compared and frequent mistakes and pitfalls of each technique are discussed. The importance of a calibration step for each technique is emphasized, and a protocol is provided for a quick and simple calibration by a "sampling" 3-D reconstruction of limited serial sections. Trends in the usage of counting methods are analyzed in four major journals. It is hoped that this r ev i ew will be helpful, for both inv e s t i gators and manuscript rev i ewers, in clarifying some of the contentious issues in the choice and implementation of appropriate methods for particle counting in tissue sections.es
dc.formatapplication/pdfes
dc.format.extent10es
dc.languageenges
dc.publisherMurcia : F. Hernándezes
dc.relation.ispartofHistology and histopathologyes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectStereologyes
dc.subjectOptical disectores
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicina::612 - Fisiologíaes
dc.titleCounting particles in tissue sections: Choices of methods and importance of calibration to minimize biaseses
dc.typeinfo:eu-repo/semantics/articlees
Aparece en las colecciones:Vol.17, nº 2 (2002)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Counting particles in tissue sections.pdf206,45 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de Digitum están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.