Por favor, use este identificador para citar o enlazar este ítem:
https://doi.org/10.1186/s12917-016-0760-2


Título: | Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs. |
Fecha de publicación: | 2016 |
Editorial: | BioMed Central |
Cita bibliográfica: | BMC Veterinary Research, 12(1) |
ISSN: | 1746-6148 |
Palabras clave: | Bathocuproinedisulfonic acid CUPRAC Dogs Oxidative stress Validation |
Resumen: | Background: The objective of the present study was to optimize and validate an automated method to assess the total antioxidant capacity (TAC) in serum of dogs using the cupric reducing antioxidant capacity (CUPRAC) methodology (TACc) with bathocuproinedisulfonic acid disodium salt as chelating agent, evaluating also possible variations due to the use of two different automated analyzers. The method is based on the reduction of Cu2+ into Cu1+ by the action of the non-enzymatic antioxidants that are present in the sample. Results: Imprecision was low in both apparatus utilized, and the results were linear across serial Trolox and canine serum samples dilutions. Lipids did not interfere with the assay; however, hemolysis increased the TACc concentrations. When TACc concentrations were determined in ten healthy (control) dogs and in twelve dogs with inflammatory bowel disease (IBD), dogs with IBD had lower TACc concentrations when compared with the healthy dogs. Conclusions: The method validated in this paper is precise, simple, and fast and can be easily adapted to automated analyzers. |
Autor/es principal/es: | Peres Rubio, Camila Tvarijonaviciute, Asta Martínez-Subiela, Silvia Hernández-Ruiz, J. Cerón, J.J. |
Versión del editor: | https://bmcvetres.biomedcentral.com/articles/10.1186/s12917-016-0760-2#citeas |
URI: | http://hdl.handle.net/10201/149930 |
DOI: | https://doi.org/10.1186/s12917-016-0760-2 |
Tipo de documento: | info:eu-repo/semantics/article |
Número páginas / Extensión: | 8 |
Derechos: | info:eu-repo/semantics/openAccess Attribution-NonCommercial-NoDerivatives 4.0 Internacional |
Descripción: | © 2016 The authors. This document is the published version of a published work that appeared in final form in BMC Veterinary Research. This document is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0. To access the final edited and published work see: https://doi.org/10.1186/s12917-016-0760-2 |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Validation of an automated assay-CUPRAC.pdf | 699,68 kB | Adobe PDF | ![]() Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons