Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.1080/17461391.2016.1249031

Título: Sprint performance and mechanical outputs computed with an iPhone app: Comparison with existing reference methods
Fecha de publicación: may-2017
Editorial: Wiley
Cita bibliográfica: European Journal of Sport Science, 2017, Vol. 17, Issue 4, 386-392
ISSN: Print: 1746-1391
Electronic: 1536-7290
Palabras clave: Acceleration
Technology
Biomechanics
Testing
Resumen: The purpose of this study was to assess validity and reliability of sprint performance outcomes measured with an iPhone application (named: MySprint) and existing field methods (i.e. timing photocells and radar gun). To do this, 12 highly trained male sprinters performed 6 maximal 40-m sprints during a single session which were simultaneously timed using 7 pairs of timing photocells, a radar gun and a newly developed iPhone app based on high-speed video recording. Several split times as well as mechanical outputs computed from the model proposed by Samozino et al. [(2015). A simple method for measuring power, force, velocity properties, and mechanical effectiveness in sprint running. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/sms.12490] were then measured by each system, and values were compared for validity and reliability purposes. First, there was an almost perfect correlation between the values of time for each split of the 40-m sprint measured with MySprint and the timing photocells (r = 0.989–0.999, standard error of estimate = 0.007–0.015 s, intraclass correlation coefficient (ICC) = 1.0). Second, almost perfect associations were observed for the maximal theoretical horizontal force (F0), the maximal theoretical velocity (V0), the maximal power (Pmax) and the mechanical effectiveness (DRF – decrease in the ratio of force over acceleration) measured with the app and the radar gun (r = 0.974–0.999, ICC = 0.987–1.00). Finally, when analysing the performance outputs of the six different sprints of each athlete, almost identical levels of reliability were observed as revealed by the coefficient of variation (MySprint: CV = 0.027–0.14%; reference systems: CV = 0.028–0.11%). Results on the present study showed that sprint performance can be evaluated in a valid and reliable way using a novel iPhone app.
Autor/es principal/es: Romero Franco, Natalia
Jiménez Reyes, Pedro
Castaño Zambudio, Adrián
Capelo Ramírez, Fernando
Rodríguez Juan, Juan José
González Hernández, Jorge
Toscano Bendala, Francisco Javier
Cuadrado Peñafiel, Víctor
Balsalobre Fernández, Carlos
Facultad/Departamentos/Servicios: Facultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Fisioterapia
Versión del editor: https://onlinelibrary.wiley.com/doi/10.1080/17461391.2016.1249031
URI: http://hdl.handle.net/10201/149780
DOI: https://doi.org/10.1080/17461391.2016.1249031
Tipo de documento: info:eu-repo/semantics/article
Número páginas / Extensión: 8
Derechos: info:eu-repo/semantics/openAccess
Atribución-NoComercial 4.0 Internacional
Descripción: © 2016 European College of Sport Science. This manuscript version is made available under the CC-BY-NC 4.0 license http://creativecommons.org/licenses/by-nc/4.0/ This document is the Published Manuscript version of a Published Work that appeared in final form in European Journal of Sport Science. To access the final edited and published work see https://doi.org/10.1080/17461391.2016.1249031
Aparece en las colecciones:Artículos: Fisioterapia



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons