Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.1148/radiol.2522082064

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorBerná Mestre, Juan de Dios-
dc.contributor.authorBerna Serna, Juan de Dios-
dc.contributor.authorAparicio Mesón, Martín-
dc.contributor.authorCanteras Jordana, Manuel-
dc.date.accessioned2025-01-22T11:27:40Z-
dc.date.available2025-01-22T11:27:40Z-
dc.date.issued2009-07-01-
dc.identifier.citationRadiology. 2009 Jul; 252(1): 240–6.es
dc.identifier.issnPrint.: 0033-8419-
dc.identifier.issnElectronic.: 1527-1315-
dc.identifier.urihttp://hdl.handle.net/10201/149062-
dc.description© RSNA, 2009 This document is the published version of a published work that appeared in final form in Radiology To access the final edited and published work see: https://doi.org/10.1148/radiol.2522082064-
dc.description.abstractTo compare examination adequacy and patient discomfort during retrograde urethrography (RUG) performed by using the conventional balloon method versus those of RUG and voiding cystourethrography (VCUG) performed with he clamp method of using drip infusion for the administration of contrast material. Materials and Methods: This prospective study was approved by the institutional review board; written informed consent was obtained from all patients. Eighty men (mean age, 64.3 years; range, 18 – 85 years) suspected of having urethral stenosis were randomly distributed into two groups for urethrography: a control group (n 36) and a clamp group (n 44). In 11 of the 36 patients in the control group, the conventional balloon method could not be used, so these patients were transferred to the clamp group. Drip infusion was used to administer contrast material for RUG, and, except in cases where a suprapubic catheter was used (n 8), for VCUG. The pain levels reported by patients were recorded by using a verbal descriptor scale (VDS) and a visual analogue scale (VAS). Results: In the control group, RUG was successfully performed in 69% of patients (25 of 36), and mean pain levels recorded on inflation of the balloon were distressing according to the VDS and 4.8 (range, 2.3–7.5) according to the VAS. In the clamp group, RUG was successfully performed in all cases; in 69% of patients in this group (38 of 55), the pain level recorded at external compression was no pain according to the VDS and 0 according to the VAS, while mean values in the remaining 31% of patients (17 of 55) were mild pain on the VDS and 0.6 (range, 0.3–1.2) on the VAS. Bladder filling for VCUG was achieved with drip infusion in 96% of patients (69 of 72) in an average time of 11 minutes. Conclusion: The conventional balloon method of performing RUG is painful and, in some cases, not effective. The clamp method is a simple, well-tolerated procedure that allowed diagnostic evaluation in all cases. Drip infusion enables RUG and VCUG to be performed without the need for syringes or bladder catheters, thus increasing patient comfort.es
dc.formatapplication/pdfes
dc.format.extent9es
dc.languageenges
dc.publisherRadiological Society of North Americaes
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/embargoedAccesses
dc.subjectUrethraes
dc.subjectRadiographyes
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicina::615 - Farmacología. Terapéutica. Toxicología. Radiologíaes
dc.titleUrethrography in Men: Conventional Technique versus Clamp Methodes
dc.typeinfo:eu-repo/semantics/articlees
dc.relation.publisherversionhttps://pubs.rsna.org/doi/10.1148/radiol.2522082064-
dc.identifier.doihttps://doi.org/10.1148/radiol.2522082064-
dc.contributor.departmentDepartamento de Dermatología, Estomatología, Radiología y Medicina Física-
Aparece en las colecciones:Artículos

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Urethrography Radiology,2009.pdfMétodo clamp de uretrografia379,79 kBAdobe PDFVista previa
Visualizar/Abrir    Solicitar una copia


Los ítems de Digitum están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.