Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.3390/ma15155100

Título: Electrical potentiometry with intraoral applications
Fecha de publicación: 22-jul-2022
Editorial: MDPI
Cita bibliográfica: Materials, 2022, Vol. 15 (15): 5100
ISSN: Print: 1996-1944
Palabras clave: Corrosion
Dental implants
Biocompatible materials/chemistry
Electrochemical techniques
Saliva
Artificial chemistry
Resumen: Dental implants currently in use are mainly made of titanium or titanium alloys. As these metallic elements are immersed in an electrolytic medium, galvanic currents are produced between them or with other metals present in the mouth. These bimetallic currents have three potentially harmful effects on the patient: micro-discharges, corrosion, and finally, the dispersion of metal ions or their oxides, all of which have been extensively demonstrated in vitro. In this original work, a system for measuring the potentials generated in vivo is developed. Specifically, it is an electrogalvanic measurements system coupled with a periodontal probe that allows measurement of the potentials in the peri-implant sulcus. This device was tested and verified in vitro to guarantee its applicability in vivo. As a conclusion, this system is able to detect galvanic currents in vitro and it can be considered capable of being employed in vivo, so to assess the effects they may cause on dental implants.
Autor/es principal/es: Jornet-García, Alfonso
Sanchez-Perez, Arturo
Montoya-Carralero, José María
Moya Villaescusa, María José
Facultad/Departamentos/Servicios: Facultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Dermatología, Estomatología, Radiología y Medicina Física
Versión del editor: https://www.mdpi.com/1996-1944/15/15/5100
URI: http://hdl.handle.net/10201/143563
DOI: https://doi.org/10.3390/ma15155100
Tipo de documento: info:eu-repo/semantics/article
Número páginas / Extensión: 11
Derechos: info:eu-repo/semantics/openAccess
Atribución 4.0 Internacional
Descripción: © 2022 by the authors. This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by/4.0/ This document is the Published version of a Published Work that appeared in final form in Materials. To access the final edited and published work see https://doi.org/10.3390/ma15155100
Aparece en las colecciones:Artículos: Dermatología, Estomatología, Radiología y Medicina Física

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
materials-15-05100.pdf2,9 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons