Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.3390/app13063936

Título: Influence of the number of microthreads on marginal bone loss: a five-year retrospective clinical study in humans
Fecha de publicación: 20-mar-2023
Editorial: MDPI
Cita bibliográfica: Applied Sciences, 2023, Vol. 13 (6): 3936
ISSN: Electronic: 2076-3417
Palabras clave: Dental implant
Alveolar bone
Microthreads
Peri-implant bone loss
Implant designs
Resumen: The purpose of the present study was to evaluate the clinical and radiographic outcomes of the number of microthreads on marginal bone over 5 years. Thirty-two implants were placed in 32 patients with partially edentulous maxillae or mandibles. Two implants with the same characteristics were placed: the first one had a 1 mm crest module and 3 microthreads (Q); and the second one had a 3 mm crest module and nine microthreads (S). The prosthesis was inserted 3 months after implant placement. Clinical and radiographic examinations were performed at the one-week, one-month, and three-month follow-up visits and then every six months until a five-year follow-up period was completed. After 5 years of follow-up, five patients withdrew from the study. Complete data were available for 27 implants, with a 100% implant survival rate. No cases of peri-implantitis were diagnosed. The average bone loss was 0.65 mm (C.I. 0.21–1.09) for Q implants and 0.86 mm (C.I. 0.39–1.33) for S implants, with no statistically significant difference. The bone level does not vary between implants with three and nine microthreads or with a 1 mm and 3 mm crest module. No differences in clinical parameters were found.
Autor/es principal/es: Jornet-García, Alfonso
Sánchez-Pérez, Arturo
Planes-Nicolás, Pablo
Montoya-Carralero, José M.
Moya Villaescusa, María José
Facultad/Departamentos/Servicios: Facultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Dermatología, Estomatología, Radiología y Medicina Física
Versión del editor: https://www.mdpi.com/2076-3417/13/6/3936
URI: http://hdl.handle.net/10201/143558
DOI: https://doi.org/10.3390/app13063936
Tipo de documento: info:eu-repo/semantics/article
Número páginas / Extensión: 13
Derechos: info:eu-repo/semantics/openAccess
Atribución 4.0 Internacional
Descripción: © 2023 by the authors. This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by/4.0/ This document is the Published version of a Published Work that appeared in final form in Applied Sciences. To access the final edited and published work see https://doi.org/10.3390/app13063936
Aparece en las colecciones:Artículos: Dermatología, Estomatología, Radiología y Medicina Física

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
applsci-13-03936.pdf1,23 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons