Por favor, use este identificador para citar o enlazar este ítem:
10.1111/pace.13824
![](/digitum/image/email_logo.png)
![](/digitum/image/logo-facebook.png)
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Arribas, José María | - |
dc.contributor.author | Soriano, Laura | - |
dc.contributor.author | Rivera Caravaca, José Miguel | - |
dc.contributor.author | Lorenzo, Maydelin | - |
dc.contributor.author | Muñoz, Carmen | - |
dc.contributor.author | Taboada, Rubén | - |
dc.contributor.author | Jiménez, Antonio | - |
dc.contributor.author | Martínez, Juan | - |
dc.contributor.author | García Puente, Julio | - |
dc.contributor.author | Gutiérrez, Francisco | - |
dc.contributor.author | Manzano, Sergio | - |
dc.contributor.author | Cánovas López, Sergio | - |
dc.date.accessioned | 2024-07-18T11:28:01Z | - |
dc.date.available | 2024-07-18T11:28:01Z | - |
dc.date.issued | 2019-11-02 | - |
dc.identifier.citation | Pacing and Clinical Electrophysiology Volume 42, Issue 12 p. 1534-1540 | es |
dc.identifier.uri | http://hdl.handle.net/10201/143223 | - |
dc.description.abstract | Background Aortic stenosis is currently the most frequently occurring valve pathology. Developments, such as transcatheter prostheses and rapid deployment prostheses, allow for the offer of a valve replacement to higher risk patients, but these techniques are linked with a higher need for a permanent pacemaker during the immediate postoperative period. Methods We studied the incidence and the factors associated with permanent pacemaker implantation after aortic valve replacement with Edwards Intuity rapid deployment prosthesis. Results Between October 2012 and December 2016, the Edwards Intuity prosthesis was implanted in 71 patients (68% male, 75.3 ± 5 years old). Six patients (8%) required a permanent pacemaker during immediate postoperative period. Univariate analysis showed that a history of acute myocardial infarction (AMI) (P = .046, B = 7.5, 95% CI [1.039-54.1]) and preoperative amiodarone (P = .009, B = 31.5; 95% CI [2.32-426]) were associated with a higher need for a pacemaker during the postoperative period. Conclusions The incidence of permanent pacemaker implantation during the immediate postoperative period of aortic valve replacement with Edwards Intuity prosthesis was 8%, a value which is within the limits reported for conventional aortic prostheses. Preoperative amiodarone treatment and previous AMI may increase the need for a pacemaker during the postoperative period of these aortic prostheses. | es |
dc.format | application/pdf | es |
dc.format.extent | 6 | es |
dc.language | eng | es |
dc.relation | Sin financiación externa a la Universidad | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | amiodarone | es |
dc.subject | aortic stenosis | es |
dc.subject | aortic valve replacement | es |
dc.subject | postoperative permanent pacemaker | es |
dc.subject | rapiddeployment aortic valve | es |
dc.title | Incidence and causes of pacemaker implantation during postoperative period of aortic valve replacement with rapid deployment prosthesis | es |
dc.type | info:eu-repo/semantics/article | es |
dc.identifier.doi | 10.1111/pace.13824 | - |
Aparece en las colecciones: | Artículos: Cirugía, Pediatría y Obstetricia y Ginecología |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Pacing Clinical Electrophis - 2019 - Arribas - Incidence and causes of pacemaker implantation during postoperative period.pdf | 419,43 kB | Adobe PDF | Visualizar/Abrir Solicitar una copia |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons