Por favor, use este identificador para citar o enlazar este ítem: 10.1111/pace.13824

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorArribas, José María-
dc.contributor.authorSoriano, Laura-
dc.contributor.authorRivera Caravaca, José Miguel-
dc.contributor.authorLorenzo, Maydelin-
dc.contributor.authorMuñoz, Carmen-
dc.contributor.authorTaboada, Rubén-
dc.contributor.authorJiménez, Antonio-
dc.contributor.authorMartínez, Juan-
dc.contributor.authorGarcía Puente, Julio-
dc.contributor.authorGutiérrez, Francisco-
dc.contributor.authorManzano, Sergio-
dc.contributor.authorCánovas López, Sergio-
dc.date.accessioned2024-07-18T11:28:01Z-
dc.date.available2024-07-18T11:28:01Z-
dc.date.issued2019-11-02-
dc.identifier.citationPacing and Clinical Electrophysiology Volume 42, Issue 12 p. 1534-1540es
dc.identifier.urihttp://hdl.handle.net/10201/143223-
dc.description.abstractBackground Aortic stenosis is currently the most frequently occurring valve pathology. Developments, such as transcatheter prostheses and rapid deployment prostheses, allow for the offer of a valve replacement to higher risk patients, but these techniques are linked with a higher need for a permanent pacemaker during the immediate postoperative period. Methods We studied the incidence and the factors associated with permanent pacemaker implantation after aortic valve replacement with Edwards Intuity rapid deployment prosthesis. Results Between October 2012 and December 2016, the Edwards Intuity prosthesis was implanted in 71 patients (68% male, 75.3 ± 5 years old). Six patients (8%) required a permanent pacemaker during immediate postoperative period. Univariate analysis showed that a history of acute myocardial infarction (AMI) (P = .046, B = 7.5, 95% CI [1.039-54.1]) and preoperative amiodarone (P = .009, B = 31.5; 95% CI [2.32-426]) were associated with a higher need for a pacemaker during the postoperative period. Conclusions The incidence of permanent pacemaker implantation during the immediate postoperative period of aortic valve replacement with Edwards Intuity prosthesis was 8%, a value which is within the limits reported for conventional aortic prostheses. Preoperative amiodarone treatment and previous AMI may increase the need for a pacemaker during the postoperative period of these aortic prostheses.es
dc.formatapplication/pdfes
dc.format.extent6es
dc.languageenges
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectamiodaronees
dc.subjectaortic stenosises
dc.subjectaortic valve replacementes
dc.subjectpostoperative permanent pacemakeres
dc.subjectrapiddeployment aortic valvees
dc.titleIncidence and causes of pacemaker implantation during postoperative period of aortic valve replacement with rapid deployment prosthesises
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1111/pace.13824-
Aparece en las colecciones:Artículos: Cirugía, Pediatría y Obstetricia y Ginecología



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons