Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.5755/j02.ms.28198

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCabello Malagón, Inmaculada-
dc.contributor.authorCánovas Hernández, Basilio-
dc.contributor.authorMartínez Hernández, Elisa-
dc.contributor.authorSerna Muñoz, Clara-
dc.contributor.authorPérez Silva, Amparo-
dc.contributor.authorOrtiz Ruiz, Antonio José-
dc.contributor.otherFacultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Dermatología, Estomatología, Radiología y Medicina Física-
dc.date.accessioned2024-06-19T11:47:37Z-
dc.date.available2024-06-19T11:47:37Z-
dc.date.issued2022-02-18-
dc.identifier.citationMaterials Science, 2022, vol. 28(1), pp. 113-119es
dc.identifier.issnPrint: 1392-1320-
dc.identifier.issnElectronic: 2029-7289-
dc.identifier.urihttp://hdl.handle.net/10201/142460-
dc.description© 2018 by the author(s) with the first publication right granted to the journal. This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by/4.0/ This document is the Published version of a Published Work that appeared in final form in Materials Science. To access the final edited and published work see https://doi.org/10.5755/j02.ms.28198-
dc.description.abstractGlass ionomer cements (GICs) are currently the first-choice materials in minimally invasive dentistry and are widely used in paediatric dentistry. The objective of this study was to evaluate the influence of viscosity and mixing on porosity and the relationship between the porosity and microhardness of GICs. Nine GICs were used: EQUIA® Forte Fil, Ionostar®Plus, 3MTMKetacTM Universal AplicapTM, Riva Light Cure HV®, Riva Silver®, Riva Protect®, VitremerTM, VitrebondTM Plus and Activa BioActive RestorativeTM. Samples were prepared from each material and images were obtained by scanning electron microscopy (SEM). Using software, the number and diameter of pores, area, and percentage of area they occupied were measured. After SEM analysis, the samples were used to make surface microhardness (SMH) measurements. Ionostar® Plus, EQUIA® Forte Fil and Riva Light Cure HV® had the highest number of pores. Riva Protect® had the largest pores and the highest percentage of pore-occupied area, while Activa BioActive RestorativeTM and VitrebondTM Plus had a smaller pore size and a smaller percentage by area. Riva Silver® and EQUIA® Forte Fil showed the highest microhardness values and VitrebondTM Plus and VitremerTM the lowest. In conclusion, when the cement viscosity is low, the type of mixture determines the degree of porosity, but has less influence when viscosity is high. There was no correlation between microhardness and the porosity of GICs.es
dc.formatapplication/pdfes
dc.format.extent7es
dc.languageenges
dc.publisherKaunas University of Technology (Lithuania)-
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectPorosityes
dc.subjectScanning electron microscopyes
dc.subjectGlass ionomer cementes
dc.subjectViscosityes
dc.subjectManual and mechanical mixinges
dc.titleAnalysis of the porosity and microhardness of glass ionomer cementses
dc.typeinfo:eu-repo/semantics/articlees
dc.relation.publisherversionhttps://matsc.ktu.lt/index.php/MatSc/article/view/28198-
dc.identifier.doihttps://doi.org/10.5755/j02.ms.28198-
Aparece en las colecciones:Artículos: Dermatología, Estomatología, Radiología y Medicina Física

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
28198-Article Text-106747-1-10-20220218.pdf698,34 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons