Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.1016/j.jelekin.2020.102456

Título: Intra- and inter-rater reliability of electrical impedance myography using adhesive electrodes in healthy volunteers
Fecha de publicación: 2-sep-2020
Editorial: Elsevier
Cita bibliográfica: Journal of Electromyography and Kinesiology, 55 (2020) 102456
ISSN: Electronic: 1050-6411
Materias relacionadas: Fisioterapia
Palabras clave: Electrical impedance myography
Reliability measures
Agreement
Muscle
Resumen: In spite of the growing use of the electrical impedance myography (EIM) measures for clinical assessment and follow-up of diseased muscle tissue, reliability studies are scarce. We evaluate the reliability of the (EIM) technique using four adhesive electrodes over the muscle of interest. Intra- and inter-rater reliability was studied within the same session and between sessions. Thirty-one healthy and volunteer subjects aged between 20 and 26 years were recruited. Phase angle, reactance and resistance were assessed for each EIM measurement. Intraclass correlation coefficient (ICC) was used to determine the relative reliability. Absolute reliability was expressed as the standard error of measurement and the minimum detectable change. Relative reliability within the same session and between sessions for the EIM technique was excellent (ICCs > 0.9) concerning both intra- and inter-rater reliability, except for the component reactance. The absolute reliability was very high for the three EIM components. EIM measures using four adhesive electrodes over the area of interest is a reliable technique to assess muscle tissue status. This study confirms that these measurement results barely vary depending on the examiner and the moment. The present study also confirms phase angle as the least affected EIM component by examiner and evaluation moment.
Autor/es principal/es: Martínez González, Mariano
Montilla Herrador, Joaquina
García Vidal, Jose Antonio
Escolar Reina, Pilar
Gacto Sánchez, Mariano
Medina Mirapeix, Francesc
Facultad/Departamentos/Servicios: Facultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Fisioterapia
URI: http://hdl.handle.net/10201/138737
DOI: https://doi.org/10.1016/j.jelekin.2020.102456
Tipo de documento: info:eu-repo/semantics/article
Número páginas / Extensión: 6
Derechos: info:eu-repo/semantics/embargoedAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Descripción: ©2020. This document is the Accepted, version of a Published Work that appeared in final form in Journal of Electromyography and Kinesiology. To access the final edited and published work see https://doi.org/10.1016/j.jelekin.2020.102456
Aparece en las colecciones:Artículos: Fisioterapia

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Intra- and inter-rater reliability-2020.pdfArtículo revista1,5 MBAdobe PDFVista previa
Visualizar/Abrir    Solicitar una copia


Los ítems de Digitum están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.