Por favor, use este identificador para citar o enlazar este ítem:
https://doi.org/10.3390/jcm8111851
Twittear
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Martín San Agustín, Rodrigo | - |
dc.contributor.author | García Vidal, José A. | - |
dc.contributor.author | Cánovas Ambit, Germán | - |
dc.contributor.author | Arenas Dalla Vecchia, Aurelio | - |
dc.contributor.author | López Nicolás, Manuel | - |
dc.contributor.author | Medina Mirapeix, Francesc | - |
dc.contributor.other | Facultad de Química, Departamento de Electromagnetismo y Electrónica | es |
dc.coverage.spatial | Laboratorio clínico | es |
dc.coverage.temporal | Siglo XXI | es |
dc.date.accessioned | 2024-02-01T11:36:22Z | - |
dc.date.available | 2024-02-01T11:36:22Z | - |
dc.date.created | 2019-10-09 | - |
dc.date.issued | 2019-11-02 | - |
dc.identifier.citation | Journal of Clinical Medicine, 2019, 8, 1851 | es |
dc.identifier.issn | 2077-0383 | - |
dc.identifier.uri | http://hdl.handle.net/10201/138401 | - |
dc.description | ©2019. This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Published, version of a Published Work that appeared in final form in Journal of Clinical Medicine . To access the final edited and published work see https://doi.org/10.3390/jcm8111851 | - |
dc.description.abstract | The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland-Altmann plots. Intra- and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Both instruments showed excellent correlation for all movements (r range from 0.992 to 0.999). The intra- and inter-rater reliability were excellent (ICC range from 0.95 to 0.99 and 0.90 to 0.98, respectively). Intra-rater reliability showed SEMs <1.38% and <5.19% and inter-rater reliability SEMs <2.26% and <5.22% for asymptomatic and symptomatic, respectively. Veloflex-IDA is a valid and reliable alternative to measure the upper limb joints' ROM and it can be used in clinical practice and research after basic training. | es |
dc.format | application/pdf | es |
dc.format.extent | 11 | es |
dc.language | eng | es |
dc.publisher | MDPI | es |
dc.relation | Sin financiación externa a la Universidad | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | - |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Range of motion | es |
dc.subject | Upper limb joints | - |
dc.subject | Biomedical technology | - |
dc.subject.other | CDU::6 - Ciencias aplicadas::62 - Ingeniería. Tecnología | es |
dc.title | Validity and realiability of a new optoelectronic system for measuring active range of motion of upper limb joints in asymptomatic and symptomatic subjects | es |
dc.type | info:eu-repo/semantics/article | es |
dc.identifier.doi | https://doi.org/10.3390/jcm8111851 | - |
Aparece en las colecciones: | Artículos: Electromagnetismo y Electrónica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Validation of Veloflex.pdf | Validation of an optoelectronic system for measuring range of motion | 1,44 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons