Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.3390/jcm8111851

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorMartín San Agustín, Rodrigo-
dc.contributor.authorGarcía Vidal, José A.-
dc.contributor.authorCánovas Ambit, Germán-
dc.contributor.authorArenas Dalla Vecchia, Aurelio-
dc.contributor.authorLópez Nicolás, Manuel-
dc.contributor.authorMedina Mirapeix, Francesc-
dc.contributor.otherFacultad de Química, Departamento de Electromagnetismo y Electrónicaes
dc.coverage.spatialLaboratorio clínicoes
dc.coverage.temporalSiglo XXIes
dc.date.accessioned2024-02-01T11:36:22Z-
dc.date.available2024-02-01T11:36:22Z-
dc.date.created2019-10-09-
dc.date.issued2019-11-02-
dc.identifier.citationJournal of Clinical Medicine, 2019, 8, 1851es
dc.identifier.issn2077-0383-
dc.identifier.urihttp://hdl.handle.net/10201/138401-
dc.description©2019. This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Published, version of a Published Work that appeared in final form in Journal of Clinical Medicine . To access the final edited and published work see https://doi.org/10.3390/jcm8111851-
dc.description.abstractThe aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland-Altmann plots. Intra- and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Both instruments showed excellent correlation for all movements (r range from 0.992 to 0.999). The intra- and inter-rater reliability were excellent (ICC range from 0.95 to 0.99 and 0.90 to 0.98, respectively). Intra-rater reliability showed SEMs <1.38% and <5.19% and inter-rater reliability SEMs <2.26% and <5.22% for asymptomatic and symptomatic, respectively. Veloflex-IDA is a valid and reliable alternative to measure the upper limb joints' ROM and it can be used in clinical practice and research after basic training.es
dc.formatapplication/pdfes
dc.format.extent11es
dc.languageenges
dc.publisherMDPIes
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectRange of motiones
dc.subjectUpper limb joints-
dc.subjectBiomedical technology-
dc.subject.otherCDU::6 - Ciencias aplicadas::62 - Ingeniería. Tecnologíaes
dc.titleValidity and realiability of a new optoelectronic system for measuring active range of motion of upper limb joints in asymptomatic and symptomatic subjectses
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doihttps://doi.org/10.3390/jcm8111851-
Aparece en las colecciones:Artículos: Electromagnetismo y Electrónica

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Validation of Veloflex.pdfValidation of an optoelectronic system for measuring range of motion1,44 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons