Por favor, use este identificador para citar o enlazar este ítem:
https://doi.org/10.1364/OE.404296
Twittear
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Fernandez, Enrique J. | - |
dc.contributor.author | Fernandez, Enrique J. | - |
dc.contributor.author | Suchkov, Nikolai | - |
dc.contributor.author | Artal, Pablo | - |
dc.contributor.other | Facultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Física | es |
dc.date.accessioned | 2024-01-31T09:47:38Z | - |
dc.date.available | 2024-01-31T09:47:38Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | Optics Express Vol. 28, Issue 25, pp. 37450-37458 (2020) | es |
dc.identifier.issn | Electronic 1094-4087 | - |
dc.identifier.uri | http://hdl.handle.net/10201/138260 | - |
dc.description | ©<2020>. This manuscript version is made available under the CC-BY-NC 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the, Published, version of a Published Work that appeared in final form in Optics Express. To access the final edited and published work see: https://doi.org/10.1364/OE.404296 | - |
dc.description.abstract | Some aspects of vision after correcting the longitudinal chromatic aberration (LCA) of the eye are not yet completely understood. For instance, correcting the LCA notably alters the through focus visual acuity (VA) curve, but it does not improve the best VA obtained for the natural case. In this work, vision with corrected LCA is further investigated by using an adaptive optics visual simulator (AOVS). VA was measured continuously during 20 minutes in 5 subjects under both natural and corrected LCA conditions to explore possible adaptation effects. Low contrast VA as a function of time exhibited a consistent and significant boost of 0.19 in decimal scale after an average time of 10.9 minutes of continuous testing. For high contrast, only one subject showed a similar increase in VA. These results suggest that some LCA neural adaptation may exist, particularly for low contrast. This adaptation impacts the performance of vision under corrected LCA, and possibly prevents measurement for immediate visual benefit. The results have practical implications for the design and visual testing of optical aids, especially those correcting, or altering, the LCA. | es |
dc.format | application/pdf | es |
dc.format.extent | 9 | es |
dc.language | eng | es |
dc.publisher | Optica Publishing Group | es |
dc.relation | Agencia Estatal de Investigación (PID2019-105684RB-I00); Fundación Séneca (19897/GERM/15, 20513/PDC/18); H2020 Marie Skłodowska-Curie Actions (675137). | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Adaptive optics | es |
dc.subject | Visual optics | es |
dc.subject | Chromatic aberration | es |
dc.subject.other | CDU::5 - Ciencias puras y naturales::53 - Física::535 - Óptica | es |
dc.title | Adaptation to the eye’s chromatic aberration measured with an adaptive optics visual simulator | es |
dc.type | info:eu-repo/semantics/article | es |
dc.relation.publisherversion | https://opg.optica.org/oe/fulltext.cfm?uri=oe-28-25-37450&id=444008 | es |
dc.identifier.doi | https://doi.org/10.1364/OE.404296 | - |
Aparece en las colecciones: | Artículos: Física |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2020FernandezOE_AdaptationChroAber.pdf | 2,4 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons