Por favor, use este identificador para citar o enlazar este ítem: doi.org/10.1038/s41598-021-99218-8

Título: Primary stability and PES/WES evaluation for immediate implants in the aesthetic zone: a pilot clinical double-blind randomized study
Fecha de publicación: 2021
Cita bibliográfica: 20024
Scientific Reports, nº 11
https://www.nature.com/articles/s41598-020-76984-5.pdf
ISSN: 2045-2322
Palabras clave: PES/WES evaluation
Primary stability
aesthetic zone
dental implants
Autor/es principal/es: Sanchez Perez, A. J.
Nicolás Silvente, Ana Isabel
Sanchez-Matas, C.
Molina-García, Silvia
Navarro-Cuellar, Carlos
Romanos, G.E.
URI: http://hdl.handle.net/10201/119461
DOI: doi.org/10.1038/s41598-021-99218-8
Tipo de documento: info:eu-repo/semantics/article
Derechos: info:eu-repo/semantics/openAccess
Atribución 4.0 Internacional
Descripción: © 2021. This manuscript version is made available under the CC-BY-4.0 license http://creativecommons.org/licenses/by/4.0/ This document is the Published Manuscript version of a Published Work that appeared in final form in Scientific Reports. To access the final edited and published work see doi.org/10.1038/s41598-021-99218-8
The use of immediate implants in the aesthetic area is a technique widely used in modern implantology. The characteristics of the patient, the implant, and the surgical procedure used may influence the final results. The aim was to assess whether the implant design affects primary (P.S.) and secondary stability (S.S.), bone level (B.L.), and PES/WES evaluation. Twenty implants with two different designs (n = 10) were immediately placed and randomly located in the upper anterior maxilla with no grafting material. Implant-Stability-Quotient (ISQ), B.L., and Pink-Esthetic-Score/White-Esthetic-Score (PES/WES) were evaluated. Shapiro–Wilk normality test was performed to determine the sample normality, as the data did not follow a normal distribution, the Wilcoxon-Mann–Whitney test was applied (p < 0.05). ISQ was determined at placement (PS): control 59.1 (C.I.54.8–63.3); experimental 62.2(C.I.60.1–64.2) and three months after placement (SS): control 62.2.1 (C.I.53.3–71.0); experimental 67.2(C.I.65.8–68.5). The BL was measured at three months after placement: control 0.38 mm (C.I.− 0.06 to + 0.83); experimental 0.76 mm (C.I.0.33–1.19) and at 12 months post-loading: control 0.07 mm (C.I.− 0.50–0.65); experimental 0.90 mm (C.I.0.38–1.42). PES/WES values were evaluated for the control group: 15 (C.I.12.68–17.32), and for the experimental group 15.20 (C.I.11.99–18.41). No significant differences were shown between both implant designs. A good grade of osseointegration and primary/secondary stability was achieved, as well as proper maintenance of crestal bone and adequate PES/WES scores. The criteria for selection for the ideal patient for immediate implant placement is essential.
Aparece en las colecciones:Artículos: Dermatología, Estomatología, Radiología y Medicina Física

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Primarystability.pdf1,42 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons