Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.6018/sportk.432111

Título: Alteraciones en la presión plantar posterior a un protocolo de fatiga neuromuscular en máquina isoinercial
Otros títulos: Alterations in plantar pressure after a protocol of neuromuscular fatigue in isoinertial machine
Fecha de publicación: 2021
Editorial: Universidad de Murcia, Servicio de publicaciones
Cita bibliográfica: Sport TK: revista euroamericana de ciencias del deporte, Vol. 10, n.º 2 (2021)
ISSN: 2340-8812
2254-4070
Materias relacionadas: CDU::7 Bellas artes::79 - Diversiones. Espectáculos. Cine. Teatro. Danza. Juegos.Deportes
Palabras clave: Baropodometría
Estabilidad
Centro de masa
Superficies de contacto
Isoinercial
Baropodometry
Stability
Center of mass
Contact surface
Isoinertial
Resumen: El objetivo del presente estudio fue establecer las diferencias que se presentan en la huella plantar tras aplicar un protocolo de fatiga neuromuscular. Un total de 10 deportistas varones sanos con una edad aproximada de 21 años fueron evaluados para el componente morfológico, con el equipo Tanita BC585F® (variables: kg de peso, kg de grasa, kg de músculo y kg de hueso). En el protocolo de fatiga se utilizó el equipo isoinercial Squat RSP®. Para la prueba de baropodometría, tanto en el pre-test como en el post-test, se utilizó el equipo EcoWalk. Se tomaron variables de presión R-Type® para ambos pies, como presión media, superficie de contacto, distribución anterior, posterior, lateral derecha y lateral izquierda. No se encontraron diferencias significativas en el pre y post test de la prueba de baropodometría con una p>0.05. Se encontraron correlaciones significativas entre el componente morfológico y la baropodometría con una p<0.05.
The objective of the present study sought to establish the differences presented in the plantar footprint after applying a neuromuscular fatigue protocol. A total of 10 healthy male athletes with an approximate age of 21 years were evaluated for the morphological component, with the Tanita BC585F® equipment (variables: weight Kg, fat KG, muscle Kg and bone Kg). In the fatigue protocol, the isoinertial Squat RSP® equipment was used. For the baropodometry test, both in the pre-test and in the post-test, the EcoWalk equipment was used. R-Type® pressure variables were taken for both feet, such as mean pressure, contact surface, anterior, posterior, right lateral and left lateral distribution. No significant differences were found in the pre and post test of the baropodometry test with a p> 0.05. Significant correlations were found between the morphological component and the baropodometry with a p <0.05.
Autor/es principal/es: Rodríguez Perdomo, Leonardo
Rincón Yepes, Camilo Andrés
Vargas Santiago, Miller Esneyder
URI: http://hdl.handle.net/10201/113224
DOI: https://doi.org/10.6018/sportk.432111
Tipo de documento: info:eu-repo/semantics/article
Número páginas / Extensión: 15
Derechos: info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Aparece en las colecciones:Vol.10, Nº 2 (2021)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
432111-Texto del artículo-1712011-1-10-20210810.pdf202,89 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons