Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10201/113037

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorSeco Nicolás, Manuel-
dc.contributor.authorAlarcón García, Mariano-
dc.contributor.authorLuna Abad, Juan Pedro-
dc.contributor.otherElectromagnetism and Electronics Department. International Campus of Excellence in the European context (CEIR) Campus Mare Nostrum, University of Murcia, Spaines
dc.date.accessioned2021-10-19T09:51:36Z-
dc.date.available2021-10-19T09:51:36Z-
dc.date.created2020-11-23-
dc.date.issued2021-07-30-
dc.identifier.isbn978-84-09-29971-3-
dc.identifier.urihttp://hdl.handle.net/10201/113037-
dc.description.abstractThe thermal inertia of the elements which compose flat plate solar thermal collectors (FPSTC) is mainly used to make previsions of temperature in order to obtain the collector performance and other related parameters. Consequently, the accurate determination of this parameter is of major interest to provide the collector performance indicators. EN 12975-2:2006 standard, establishes the procedure to obtain the thermal capacity of a FPSTC from experimental or simulated data. This standard applies a coefficient for every layer of the assembly, decreasing the role of the glass cover to less than 4%. However, the obtained experimental inertia of the glass cover was around 10%. The calculations were made using data obtained in thermo-solar experimental facility of the Solar Laboratory of the University of Murcia. Two solar collectors of different typology belonging to this facility were provided with a set of 28 thermocouples each, divided into four measurement sections. This arrangement allows the continuous measurement of the collector temperature field, as well as of fluid temperatures and other data related with collector performances. The thermal inertia of each component of one of the FPSTC has been represented in bars diagrams, during the daylight period, in steps of 10 minutes. In most cases only a slight difference of about 0.2 to 1.2 ºC between forecast temperatures, considering new elements or not, were obtained, leading to the conclusion that for general purposes the EN-12975-2:2006 standard definition of collector mean temperature is sufficiently accurate, but it could be improved.es
dc.formatapplication/pdfes
dc.format.extent18es
dc.languagespaes
dc.publisherMariano Alarcón García, Universidad de Murciaes
dc.relationSin financiación externa a la Universidades
dc.relation.ispartofV Encuentro de Ingeniería de la Energía del Campus Mare Nostrumes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectThermal inertiaes
dc.subjectflat plate solar thermal collector (FPSTC)es
dc.subjectEN-12975-2:2006es
dc.titleInfluencia real de la inercia térmica de los elementos de un captador solar plano de baja temperaturaes
dc.typeinfo:eu-repo/semantics/articlees
dc.relation.publisherversionhttps://eventos.um.es/51923/detail/v-encuentro-de-ingenieria-de-la-energia-del-campus-mare-nostrum.htmles
Aparece en las colecciones:V Encuentro de Ingeniería de la Energía del Campus Mare Nostrum

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
06_SecoNicolas.pdf06_renvoables-Seco1,96 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons