Por favor, use este identificador para citar o enlazar este ítem: https://doi.org/10.1016/j.jhazmat.2009.03.059

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorM. Gomez-
dc.contributor.authorG. Matafonova-
dc.contributor.authorJ.L. Gomez-
dc.contributor.authorV. Batoev-
dc.contributor.authorN. Christofi-
dc.contributor.otherFacultades, Departamentos, Servicios y Escuelas::Departamentos de la UMU::Ingeniería Químicaes
dc.contributor.otherBaikal Institute of Nature Management, Siberian Branch of Russian Academy of Scienceses
dc.contributor.otherPollution Research Unit, School of Life Sciences, Edinburgh Napier Universityes
dc.date.accessioned2021-03-26T11:56:51Z-
dc.date.available2021-03-26T11:56:51Z-
dc.date.created2009-
dc.date.issued2009-09-30-
dc.identifier.citationJournal of Hazardous Materials, 169 (1–3), 2009, 46-51es
dc.identifier.urihttp://hdl.handle.net/10201/105725-
dc.description© <2021>. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Accepted Manuscript version of a Published Work that appeared in final form in [Journal of Hazardous Materials]. To access the final edited and published work see [https://doi.org/10.1016/j.jhazmat.2009.03.059].es
dc.description.abstractThe removal of 4-chlorophenol (4-CP) from industrial wastewater continues to be an important environmental issue and some interesting results have been obtained using oxidoreductive enzymes such as peroxidases and UV, generated by novel excilamps. In this study enzyme (free and immobilized soybean peroxidase) and UV (produced by a KrCl excilamp) were used to treat 4-CP solutions at concentrations ranging from 50 to 500 mg L-1. It was shown that the excilamp can facilitate higher removal efficiencies in all cases with complete 4-CP elimination taking place between 5 and 90 min. The enzyme removed ~80% of the 4-CP concentrations in both the free and immobilized state up to concentrations of 250 mg L-1. At 500 mg L-1 the immobilised system shows much higher removal efficiency due to increased enzyme stability in the presence of higher formation of by-products.es
dc.formatapplication/pdfes
dc.format.extent25es
dc.languageenges
dc.publisherElsevieres
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject4-chlorophenoles
dc.subjectsoybean peroxidasees
dc.subjectexcilampes
dc.subjectimmobilizationes
dc.subjectphotodegradationes
dc.subject.otherCDU::6 - Ciencias aplicadas::66 - Ingeniería, tecnología e industria química. Metalurgiaes
dc.titleComparison of alternative treatments for 4-chlorophenol removal from aqueous solutions: Use of free and immobilized soybean peroxidase and KrCl excilampes
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doihttps://doi.org/10.1016/j.jhazmat.2009.03.059-
Aparece en las colecciones:Artículos: Ingeniería Química

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
final paper HAZMAT-D-09-00272[2] final.pdf399,82 kBAdobe PDFVista previa
Visualizar/Abrir