dc.description.abstractEsta Tesis Doctoral evalúa la norma UNE EN 14211:2006 –Método normalizado de medida de la concentración de dióxido de nitrógeno y monóxido de nitrógeno por quimiluminiscencia-, citada como referencia técnica en la Directiva 2008/50/CE sobre calidad del aire y una atmósfera más limpia en Europa. La citada norma establece ensayos y criterios que deben superar los analizadores de los contaminantes citados antes de su comercialización en la Unión Europea, lo que se conoce como ensayo de aprobación de tipo. La Tesis Doctoral elaborada estudia en profundidad esta nueva norma, llevando a cabo un estudio crítico que analiza los aspectos operativos y los criterios exigidos. En algunos casos se proponen modificaciones que pueden ayudar a mejorarla. Así mismo se sugiere aplicar procedimientos correctivos de los datos obtenidos en campo, que resultan afectados por determinados parámetros físicos (presión, temperatura y humedad), modelizables mediante el empleo de leyes físicas o ajustes empíricos. Abstract This Doctoral Thesis aims at evaluating the norm EN 14211: Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence, mentioned in the Directive 2008/50/EC as technical reference document. The above standard specifies performance parameters that the analyzers must comply with prior to being sold, what is known as “Type Approval Test”, and field calibration and verification guidelines, neither of which was considered in the previous standards. The study of the new Standard has revealed that some points could be improved in order to achieve a higher degree of accuracy and precision in the concentration data of nitrogen oxides. The improvement proposals cover certain aspects of the tests related to the Type Approval Test and data corrective procedures empirically obtained or by means of physical laws which are affected by physical parameters such as pressure, temperature or humidity.en_EN
dc.formatapplication/pdfes
dc.languagespaen_EN
dc.publisherUniversidad de Murciaen_EN
dc.relation.ispartofProyecto de investigación:en_EN
dc.relation.replaceshttp://global.tesisenred.net/TDR-0125110-093333/index_cs.html#documentsen_EN
dc.rightsLa difusión de este documento por medio de Internet ha sido autorizado por los titulares de los derechos de propiedad intelectual únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro ni su difusión.en_EN
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectAireen_EN
dc.subjectContaminación-
dc.subject.otherCDU::5 - Ciencias puras y naturales::54 - Químicaen_EN
dc.titleEvaluación de la norma UNE EN 14211:2006 para la medida de óxidos de nitrógeno en aire: Propuestas de modificacionesen_EN
dc.typeinfo:eu-repo/semantics/doctoralThesisen_EN
Aparece en las colecciones:Ciencias

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
DovalMinarro.pdf4,6 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de Digitum están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.