Publication: Histologic and histomorphometric evaluation of minicono abutment on implant surrounding tissue healing and bone resorption on implants placed in healed bone. An experimental study in dogs
Authors
Calvo Guirado, José Luis ; Cabo Pastor, Marta Belén ; Martínez Martínez, Francisco ; Garcés Villalá, Miguel Ángel ; Carlos Villafranca, Félix de ; García Carrillo, Nuria ; Fernández Domínguez, Manuel
item.page.secondaryauthor
item.page.director
Publisher
AIMS Press
publication.page.editor
publication.page.department
DOI
https://doi.org/10.3934/bioeng.2023013
item.page.type
info:eu-repo/semantics/article
Description
© 2023 the Author(s). This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by/4.0/ This document is the Published Manuscript version of a Published Work that appeared in final form in AIMS Bioengineering. To access the final edited and published work see https://doi.org/10.3934/bioeng.2023013
Abstract
The objective of this evaluation was to measure the width and length of connective tissue (CT) and crestal bone resorption (CBR) related to minicono® abutment inserted in conical connection dental implants, which were placed crestal and subcrestally in a dog's mandible.
Materials and Methods
Forty-eight Top DM implants with the same coronal diameter were placed at the crestal level, 1 mm (test 1 group) and 2 mm (test 2 group) positions underneath buccal-lingual bone crests. Dental implants used in the study were separated into three groups of 16 implants each. The implants were randomly inserted into healed bone after two months post-extraction sockets of three lower premolars, and first molar, bilaterally in six male fox hound dogs. One 3 mm minicono height abutment was connected to conical connection implants placed at the crestal level (control), 1 mm (test 1) and 2 mm (test 2) positions under buccal-lingual crests.
Results
All abutments and implants used were clinically and histologically integrated into the bone-soft tissue. Soft tissue behavior was observed at eight and 12 weeks in all test groups, displaying similar quantitative findings with significant differences (p > 0.05). However, crestal bone loss was significantly greater at the buccal side around that control group compared to the test 1 and 2 groups. The difference values between groups at the implant shoulder to the top of the lingual bone crest (IS-LBC) and the implant shoulder to the top of the buccal bone crest (IS-BBC) were significantly greater for the test 2 group in comparison with the other two groups (p < 0.05) at eight weeks. In addition, crestal bone resorption (CBR) increased in the crestal group at twelve weeks, but it was reduced for the test 1 and test 2 groups in implants placed sub-crestally (p < 0.05).
Conclusions
Crestal bone loss could be reduced using a 3 mm high abutment on implants submerged below the bone crest from 1 to 2 mm positions.