Publication:
Development of a time-resolved fluorometry based immunoassay for the determination of canine haptoglobin in various body fluids

dc.contributor.authorVäisänen, Ville
dc.contributor.authorCerón Madrigal, José Joaquín
dc.contributor.authorParra Muñoz, María Dolores
dc.contributor.departmentCiencias Sociosanitarias
dc.date.accessioned2025-01-22T08:03:39Z
dc.date.available2025-01-22T08:03:39Z
dc.date.issued2005
dc.description© INRA, EDP Sciences 2005. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/. This document is the Published version of a Published Work that appeared in final form in Veterinary Research. To access the final edited and published work see https://doi.org/10.1051/vetres:2004054es
dc.description.abstractA time-resolved immunofluorometric assay (TR-IFMA) was developed for the determination of haptoglobin (Hp) in canine serum. Haptoglobin was purified from canine acute phase serum by ammonium sulphate precipitation followed by gel filtration. This isolated dog Hp was used as the standard to calibrate the assay. Intra- and inter-assay coefficients of variation of the assay were, respectively, 5.7% and 16.6% at 0.51 mg/mL, 2.4% and 10.6% at 2.1 mg/mL and 10.5% and 11.9% at 32.5 mg/mL. The dilution of serum samples with high Hp concentrations resulted in linear regression equations with R2 of 0.99 and 0.97. A high correlation was found in serum Hp measurements by TR-IFMA and a commercial assay based on peroxidase activity of haemoglobin bound to haptoglobin (R2 = 0.96). The limit of detection for the TR-IFMA method was 0.002 µg/mL. The addition of fresh haemolysate to serum samples did not affect the haptoglobin concentration (P = 0.694). Statistical differences (P < 0.003) were found between healthy dogs and dogs with different pathological processes. In whole blood, Hp concentrations were much lower than in serum but closely related (R2 = 0.84) whereas saliva Hp concentrations were poorly related with serum concentrations (R2 =0.53). However, the concentration of Hp in saliva was significantly (P < 0.039) higher in dogs with pathological processes compared to healthy dogs. The assay sensitivity was adequate to also be applied to whole blood and saliva specimens.es
dc.formatapplication/pdfes
dc.format.extent13es
dc.identifier.citationVet. Res. 36 (2005) 117-129
dc.identifier.doihttps://doi.org/10.1051/vetres:2004054
dc.identifier.issnPrint: 0928-4249
dc.identifier.issnElectronic: 1297-9716
dc.identifier.urihttp://hdl.handle.net/10201/148984
dc.languageenges
dc.publisherINRA / EDP Scienceses
dc.relationSin financiación externa a la Universidades
dc.relation.publisherversionhttps://www.vetres.org/articles/vetres/abs/2005/01/V4041/V4041.htmles
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCaninees
dc.subjectHaptoglobines
dc.subjectTime-resolved fluorometryes
dc.subjectWhole bloodes
dc.subjectSalivaes
dc.titleDevelopment of a time-resolved fluorometry based immunoassay for the determination of canine haptoglobin in various body fluidses
dc.typeinfo:eu-repo/semantics/articlees
dspace.entity.typePublicationes
relation.isAuthorOfPublicationeac91d5a-824e-4993-860c-94af29bdfcc6
relation.isAuthorOfPublication.latestForDiscoveryeac91d5a-824e-4993-860c-94af29bdfcc6
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
haptoglobin canina 2005.pdf
Size:
355.87 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.26 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections