Por favor, use este identificador para citar o enlazar este ítem: DOI: 10.14670/HH-11-945

Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorHohmann, Tim-
dc.contributor.authorKessler, Jacqueline-
dc.contributor.authorGrabiec, Urszula-
dc.contributor.authorBache, Matthias-
dc.contributor.authorDehghani, Faramarz-
dc.date.accessioned2022-04-07T08:57:53Z-
dc.date.available2022-04-07T08:57:53Z-
dc.date.issued2018-
dc.identifier.citationHistology and Histopathology, Vol.33, nº5, (2018)es
dc.identifier.issn1699-5848-
dc.identifier.issn0213-3911-
dc.identifier.urihttp://hdl.handle.net/10201/118827-
dc.description.abstractRadiation therapy belongs to the most common approaches for cancer therapy leading amongst others to DNA damage like double strand breaks (DSB). DSB can be used as a marker for the effect of radiation on cells. For visualization and assessing the extent of DNA damage the γH2AX foci assay is frequently used. The analysis of the γH2AX foci assay remains complicated as the number of γH2AX foci has to be counted. The quantification is mostly done manually, being time consuming and leading to person-dependent variations. Therefore, we present a method to automatically analyze the number of foci inside nuclei, facilitating and quickening the analysis of DSBs with high reliability in fluorescent images. First nuclei were detected in fluorescent images. Afterwards, the nuclei were analyzed independently from each other with a local thresholding algorithm. This approach allowed accounting for different levels of noise and detection of the foci inside the respective nucleus, using Hough transformation searching for circles. The presented algorithm was able to correctly classify most foci in cases of “high” and “average” image quality (sensitivity>0.8) with a low rate of false positive detections (positive predictive value (PPV) >0.98). In cases of “low” image quality the approach had a decreased sensitivity (0.7-0.9), depending on the manual control counter. The PPV remained high (PPV >0.91). Compared to other automatic approaches the presented algorithm had a higher sensitivity and PPV. The used automatic foci detection algorithm was capable of detecting foci with high sensitivity and PPV. Thus it can be used for automatic analysis of images of varying qualityes
dc.formatapplication/pdfes
dc.format.extent11es
dc.languageenges
dc.publisherUniversidad de Murcia. Departamento de Biología Celular e Histologíaes
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectγH2AXes
dc.subjectHough transformationes
dc.subjectFoci Segmentationes
dc.subjectFoci Detectiones
dc.subjectFocies
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicina::616 - Patología. Medicina clínica. Oncologíaes
dc.titleAutomatic detection of DNA double strand breaks after irradiation using an γH2AX assayes
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doiDOI: 10.14670/HH-11-945-
Aparece en las colecciones:Vol.33, nº5 (2018)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Hohmann-33-475-485-2018.pdf1,89 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons